Producción Científica Profesorado

Size exclusion chromatography (SEC-HPLC) as an alternative to study thrombin inhibition



Páez Hernández, María Elena

2018

Size exclusion chromatography (SEC-HPLC) as an alternative to study thrombin inhibition, Pérez-Escalante, E., González-Olivares, L.G., Cruz-Guerrero, A.E., Galán-Vidal, C.A., Páez-Hernández, M.E., Álvarez-Romero, G.A., Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, 1074-1075 (2018) 34-38, DOI: 10.1016/j.jchromb.2017.12.037


Abstract


In vitro analysis of anticoagulant compounds with a potential use as antithrombotic drugs, has been traditionally performed using techniques like spectrophotometry, turbidimetry, as well as electrochemical and clinical assays. Although, these techniques have some disadvantages such as: the inability to measure the total biological activity of thrombin, interferences and, sometimes, the quantitative determination of the inhibition ratio is not accurate. In the present work, the conversion of fibrinogen to fibrin was monitored by molecular exclusion chromatography (SEC-HPLC) in three different reaction systems. An inhibition percentage of 43.192.02% was obtained using heparin as an anticoagulant, in addition to the determination of the percentage of heparin bonded to thrombin. This methodology has not been previously described and has high potential for the determination of anticoagulant capacity with higher precision, the determination of thrombin's total biological activity and the quantitative determination of the inhibition ratio



Producto de Investigación




Artículos relacionados

Synthesis and crystal structures of cis-palladium(II) and cis-platinum(II) complexes containing dipy...

Design and Construction of Solid State Ag/AgCl Reference Electrodes Through Electrochemical Depositi...

Magnetic solids in analytical chemistry: A review

cis-Palladium(II) complexes of derivatives of di-(2-pyridyl)methane: Study of the influence of the b...

High-performance liquid magneto-chromatography

Potentiometric Behavior of Diverse Polypyrrolesulphate Films Electro Synthesized on Graphite Epoxy ...

Simultaneous determination of tetracyclines in poultry muscle by capillary zone electrophoresis

Mercury Ions Removal from Aqueous Solution Using an Activated Composite Membrane

Determination of primary amino acids in wines by high performance liquid magneto-chromatography

Determination of tetracyclines in milk samples by magnetic solid phase extraction flow injection ana...