Producción Científica Profesorado

Evaluation of the use of solvent impregnated resins in the analysis of salbutamol in human urine followed by capillary electrophoresis.



Rodríguez Ávila, José Antonio

2016

Irma Pérez-Silva, Ma. Teresa Ramírez-Silva, Carlos A. Galán-Vidal, Giaan A. Álvarez-Romero, José A. Rodríguez, Ma. Elena Páez-Hernández. Evaluation of the use of solvent impregnated resins in the analysis of salbutamol in human urine followed by capillary electrophoresis. Reactive and Functional Polymers, 2016, 105, 89-94


Abstract


In this work, a method for sorption and concentration of salbutamol in urine combined to capillary electrophoresis with UV detection was performed. The procedure is based on the sorption of salbutamol on solvent-impregnated resins that is prepared by an impregnation technique using Aliquat 336 as extractant and XAD-4 resin as the base polymer. Batch studies showed an efficient sorption/desorption results when the salbutamol solution contains NaOH 0.05 mol L? 1 and the eluent is 0.5 mol L? 1 NaCl. Linearity was obtained in the range of 1000?10,000 ng mL? 1 of salbutamol. The limit of quantification was 999 ng mL? 1. The solvent-impregnated resin was used for 10 cycles without a significant loss of the salbutamol quantification capacity. The method was applied to analyze salbutamol in urine samples at levels useful for international health organizations. Although most reports of solvent impregnated resins are related to the extraction of metal ions and only a few organic compounds, the proposed methodology demonstrate that solvent impregnated resins allows the isolation and concentration of salbutamol from complex samples such as urine. Since no SB is recovered using resin without Aliquat 336, this work shows an advantage of SIR over simple adsorption processes.



Producto de Investigación




Artículos relacionados

Development of a Polypyrrole Selective Membrane For The Potentiometric Quantification of Saccharinat...

Construction and Evaluation of a Gold Tubular Electrode for Flow Analysis: Application to Speciation...

Metal content evaluation and its effect on the stability of anthocyanins

Determination of non-steroidal anti-inflammatory drugs in wastewaters by magnetic matrix solid phase...

Potentiometric behavior of graphite-epoxy electrochemical transducers towards anions, cations and pH...

Determination of oxytetracycline in milk samples by polymer inclusion membrane separation coupled to...

Silver and Silver Chloride Electrodeposits, an Alternative in the Construction of Ag/AgCl Solid Elec...

Determination of primary amino acids in wines by high performance liquid magneto-chromatography

Potentiometric quantification of saccharin by using a selective membrane formed by pyrrole electropo...

Potentiometric quantification of saccharin by using a selective membrane formed by pyrrole electropo...