Producción Científica Profesorado

Multicommutated Anodic Stripping Voltammetry at Tubular Bismuth Film Electrode for Lead Determination in Gunshot Residues



Rodríguez Ávila, José Antonio

2009

Rodriguez, J.A., Ibarra, I.S., Galan-Vidal, C.A., Vega, M., Barrado, E., Multicommutated anodic stripping voltammetry at tubular bismuth film electrode for lead determination in gunshot residues, Electroanalysis, 2009, Vol. 21, p.452-458, ISSN 1040-0397


Abstract


This work describes the construction of a miniaturized flow-through electrochemical cell and its application to the determination of lead in gunshot residues (GSR) by differential-pulse anodic stripping voltammetry at bismuth films co-deposited on-line on a tubular carbon paste electrode. The developed detector was coupled to a multicommutated flow system which was designed to allow medium exchange prior to the stripping step thus reducing interferences from the analytical matrix, and to implement the standard additions method in an automatic way, using only one standard solution. For a deposition time of 60?s at ?1.5 V at a flow rate of 0.5?mL min?1 without oxygen removal, the detection limit of the method was 0.2?mg L?1. Under these conditions the linear dynamic range was 0.310.0?mg L?1 with a sampling rate of 15.0?samples h?1. Repeatability of lead concentration was 3% (n=3). The method was applied to the analysis of lead in GSR on hands of shooters and concentrations up to 16.5??g and 6.7??g were found in palms and backs, respectively. No statistically significant differences between the results obtained by the proposed and the comparative method (F-AAS) were found, at a 95% confidence level.



Producto de Investigación




Artículos relacionados

cis-Palladium(II) complexes of derivatives of di-(2-pyridyl)methane: Study of the influence of the b...

Determination of oxytetracycline in milk samples by polymer inclusion membrane separation coupled to...

Renewable stationary phase liquid magnetochromatography: determining aspartame and its hydrolysis pr...

Metal content evaluation and its effect on the stability of anthocyanins

Determination of tetracyclines in milk samples by magnetic solid phase extraction flow injection ana...

Presence and antimicrobial resistance of Escherichia coli isolated from foodstuffs in Hidalgo State ...

Determination of non-steroidal anti-inflammatory drugs in wastewaters by magnetic matrix solid phase...

Synthesis and crystal structures of cis-palladium(II) and cis-platinum(II) complexes containing dipy...

Validation of a tubular bismuth film amperometric detector: Determination of diclofenac sodium by mu...

Development of a novel composite sensor based on doped pyrrole selective to nitrate ions