Producción Científica Profesorado

Potentiometric quantification of saccharin by using a selective membrane formed by pyrrole electropolymerization



Páez Hernández, María Elena

2010

Álvarez-Romero, G.A., Lozada-Ascencio, S.M., Rodríguez-Ávila, J.A., Galán-Vidal, C.A., Páez-Hernández, M.E. Potentiometric quantification of saccharin by using a selective membrane formed by pyrrole electropolymerization. Food Chemistry, 120 (2010) 12501254. http://dx.doi.org/10.1016/j.foodchem.2009.11.072


Abstract


A selective membrane for direct quantification of saccharinate ion based on a polypyrrole-doped membrane is developed. The membrane is electrochemically prepared using stainless steel as working electrode. Potentiostatic variables for membrane growing such as pyrrole concentration, saccharinate concentration, applied potential and deposition time are optimized in order to maximize sensitivity. The optimized membrane was analytically characterized by means of calibration curves, the detection limit was found to be 3.6 × 10?4 mol L?1 and the quantification limits were found between 5 × 10?4 mol L?1 and over 1 mol L?1. Selectivity of the membrane is evaluated for different inorganic anions, resulting in the following selectivity coefficients: pKSaccharinate,Citrate = 3.4, pKSaccharinate,H2PO4 = 3.4, and .These results demonstrate an adequate performance of the proposed selective polypyrrole membrane so it can be considered as an alternative to traditional analytical methods for the direct quantification of saccharin in diverse samples.



Producto de Investigación




Artículos relacionados

Determination of glucose by flow injection analysis with amperometric detection at Fe(III)-(tris(3,5...

Development of a Chloride Ion-Selective Solid State Sensor Based on Doped Polypyrrole-Graphite-Epoxy...

Nucleation and Growth Kinetics of Electrodeposited Sulfate-Doped Polypyrrole: Determination of the D...

Chemical studies of anthocyanins: A review

Determination of tetracyclines in milk samples by magnetic solid phase extraction flow injection ana...

Validation of a tubular bismuth film amperometric detector: Determination of diclofenac sodium by mu...

Mercury Ions Removal from Aqueous Solution Using an Activated Composite Membrane

Potentiometric behavior of graphite-epoxy electrochemical transducers towards anions, cations and pH...

Potentiometric Behavior of Diverse Polypyrrolesulphate Films Electro Synthesized on Graphite Epoxy ...

Sequential Injection Spectrophotometric Determination of Diclofenac in Urine and Pharmaceutical Form...